11
11.4 Apparent Power and Power Factor (1)
•Apparent Power, S, is the product of the r.m.s. values of voltage and current. •It is measured in volt-amperes or VA to distinguish it from the average or real power which is measured in watts.
•
•
•
•
•
•
•Power factor is the cosine of the phase difference between the voltage and current. It is also the cosine of the angle of the load impedance.
Apparent Power, S
Power Factor, pf